aadr1sdd

09/04/97 djm #1

02/06/98 dlf #2

---------------------------------------------------------------

DATA DICTIONARY: AMSU/A 1B* DATA RECORD



A1-1_SCANNER_PWR - A1-1 scanner motor power flag from digital B telemetry.

Value of 1 indicates power on.



A1-1_SCANNER_PWR_FLAG - Invalid (questionable) flag for A1-1 scanner motor

power flag from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A1-2_SCANNER_PWR - A1-2 scanner motor power flag from digital B telemetry.

Value of 1 indicates power on.



A1-2_SCANNER_PWR_FLAG- Invalid (questionable) flag for A1-2 scanner motor

power flag from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A1_ANALOG_INVALID_BIT_FLAGS - Word indicating AMSU-A1

analog telemetry data is questionable. Bits in this word are set if a

given analog item corresponding to the bit could not be

updated during the scan. Bits are as defined in 1b data

format for Invalid Word Bit Flags under AMSU-A1 Analog

Housekeeping Data.



A1_ANT_IN_COLD_POS - Flag for A1 antenna in cold calibration mode from digital B

telemetry. Value of 1 indicates antenna in cold calibration mode.

A1_ANT_IN_COLD_POS_FLAG - Invalid (questionable) flag for A1 antenna in cold

cal position from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A1_ANT_IN_NADIR_POS - Flag for A1antenna in nadir view mode from digital B

telemetry. Value of 1 indicates antenna in nadir view mode.

A1_ANT_IN_NADIR_POS_FLAG - Invalid (questionable) flag for A1 antenna in nadir

view position from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A1_ANT_IN_WARM_POS - Flag for A1 antenna in warm calibration mode from

digital B telemetry. Value of 1 indicates antenna in warm calibration mode.



A1_ANT_IN_WARM_POS_FLAG - Invalid (questionable) flag for A1 antenna in warm

cal position from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A1_COLD_CAL_POS_LSB - Least significant bit of 2 bit A1 antenna position

of space view from digital B telemetry. Positions have values 0 to 3.



A1_COLD_CAL_POS_LSB_FLAG - Invalid (questionable) flag for A1 antenna space

view position LSB from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A1_COLD_CAL_POS_MSB - Most significant bit of 2 bit A1 antenna position

of space view from digital B telemetry. Positions have values 0 to 3.



A1_COLD_CAL_POS_MSB_FLAG - Invalid (questionable) flag for A1 antenna space

view position M

SB from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A1_DIG_B_INVALID_BIT_FLAGS - Word indicating AMSU-A1 digital

B telemetry data is questionable. Bits in this word are set if a

given digital B item corresponding to the bit could not be

updated during the scan. Bits are as defined in 1b data

format for Invalid Word Bit Flags under AMSU-A1 Digital

B Telemetry.



A1_DIG_B_TELEMETRY_BIT_FLAGS

Bits in this word are set if a

given digital B item corresponding to the bit is set.

Bits in this word are as defined in 1b data

format for Digital "B" Telemetry under AMSU-A1 Digital

B Telemetry.



A1_FULL_SCAN - Flag from digital B telemetry. Value of 1 implies full scan

mode. Value of 1 indicates instrument in full scan mode.



A1_FULL_SCAN_FLAG - Invalid (questionable) flag for A1 in full scan mode

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A1_MODULE_PWR - Digital B telemetry flag. 1 = A1 module power is on.

0 = A1 module power is off.



A1_MODULE_PWR_FLAG - Invalid (questionable) flag for A1 module power

flag from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A1_PHASE_LOCK_LOOP - Flag from digital B telemetry. 1 = primary PLLO (#1)

power is on. 2 = redundant PLLO (#2) power is on.



A1_PHASE_LOCK_LOOP_FLAG - Invalid (questionable) flag for A1 PLLO flag

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A1_SURVIVAL_HTR - Digital B telemetry flag. 1 = A1 survival heater power is on.

0 = A1 survival heater power is off.



A1_SURVIVAL_HTR_FLAG - Invalid (questionable) flag for A1 survival heater flag

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_ANALOG_INVALID_BIT_FLAGS - Word indicating AMSU-A2

analog telemetry data is questionable.

Bits in this word are set if a

given analog item corresponding to the bit could not be

updated during the scan. Bits are as defined in 1b data

format for Invalid Word Bit Flags under AMSU-A2 Analog

Housekeeping Data.



A2_ANT_IN_COLD_POS - Flag for A2 antenna in cold calibration mode from digital B

telemetry. Value of 1 indicates antenna in cold calibration mode.

A2_ANT_IN_COLD_POS_FLAG - Invalid (questionable) flag for A2 in cold cal mode

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_ANT_IN_NADIR_POS - Flag for A2 antenna in nadir view mode from digital B

telemetry. Value of 1 indicates antenna in nadir view mode.

A2_ANT_IN_NADIR_POS_FLAG - Invalid (questionable) flag for A2 in nadir view mode

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_ANT_IN_WARM_POS - Flag for A2 antenna in warm calibration mode from

digital B telemetry. Value of 1 indicates antenna in warm calibration mode.

A2_ANT_IN_WARM_POS_FLAG - Invalid (questionable) flag for A2 in warm cal mode

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A2_COLD_CAL_POS_LSB - Least significant bit of 2 bit A2 antenna position

of space view from digital B telemetry. Positions have values 0 to 3.



A2_COLD_CAL_POS_LSB_FLAG - Invalid (questionable) flag for A2 antenna space

view position L

SB from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A2_COLD_CAL_POS_MSB - Most significant bit of 2 bit A2 antenna position

of space view from digital B telemetry. Positions have values 0 to 3.



A2_COLD_CAL_POS_MSB_FLAG - Invalid (questionable) flag for A2 antenna space

view position M

SB from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_COMPENSATOR_MOTOR - A2 compensator motor power flag from digital B telemetry.

Value of 1 indicates power on.



A2_COMPENSATOR_MOTOR_FLAG - Invalid (questionable) flag for A2 compensator

motor flag from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_DIG_B_INVALID_BIT_FLAGS - Word indicating AMSU-A2 digital

B telemetry data is questionable. Bits in this word are set if a

given digital B item corresponding to the bit could not be

updated during the scan. Bits are as defined in 1b data

format for Invalid Word Bit Flags under AMSU-A2 Digital

B Telemetry.

A2_DIG_B_TELEMETRY_BIT_FLAGS

Bits in this word are set if a

given digital B item corresponding to the bit is set.

Bits in this word are as defined in 1b data

format for Digital "B" Telemetry under AMSU-A2 Digital

B Telemetry.

A2_FULL_SCAN - Flag from digital B telemetry. Value of 1 implies full scan

mode. Value of 1 indicates full scan mode.



A2_FULL_SCAN_FLAG - Invalid (questionable) flag for A2 full scan mode

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_MODULE_PWR - Digital B telemetry flag. 1 = A2 module power is on.

0 = A2 module power is off.



A2_MODULE_PWR_FLAG - Invalid (questionable) flag for A2 full scan mode

from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



A2_SCANNER_PWR - Digital B telemetry flag. 1 = A2 scanner motor power is on.

0 = A2 scanner power is off.



A2_SCANNER_PWR_FLAG - Invalid (questionable) flag for A2 scanner power

flag from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.

A2_SURVIVAL_HTR - Digital B telemetry flag. 1 = A2 survival heater power is on.

0 = A2 survival heater power is off.



A2_SURVIVAL_HTR_FLAG - Invalid (questionable) flag for A2 survival heater

flag from digital B telemetry. Value of 1 indicates that the value of the

digital B flag could not be updated during this scan.



AIP_MINOR_QUALITY_S/C - 4 byte quality indicator from AIP minor frame

quality words at end of AIP 1a data record. This array contains one 4 byte

word for each of 80 minor frames. Format for each word is given in 1a

requirements document.

AMSU_MAJOR_FRAME_ERROR_DETECTED - Set to 1 if major frame is filler;

otherwise 0.



AMSU_MINOR_FRAME_ERROR_DETECTED - Set to 1 if minor frame

number is filler, or AIP is filler, AMSU is filler,

or minor frame has is out of sequence.



AMSU_PARITY_ERROR_DETECTED - flag is set to 1 if any AMSU parity bits

(6 bits of 103rd byte of minor frame) is not 0.



AMSU_SYNC_ERROR_DETECTED - Flag is set to 1 if any of first 22 bits

of AMSU part of minor frame are incorrect.

APITCH represents the Euler error angle. See the

Programming and Control Handbook (Reduction of CPU Telemetry)

for instructions for the conversion of this integer value to an

angular measure.



AROLL represents the Euler error angle. See the

Programming and Control Handbook (Reduction of CPU Telemetry)

for instructions for the conversion of this integer value to an

angular measure.



ATTITUDE_CONTROL - TBD



ATTITUDE_PWTIP$AC the "passive wheel test in progress" indicator from

the TIP CPU telemetry. The two-byte hex code given in the

telemetry has been stored as a one-byte indicator that can be

interpreted as follows:

+

0 --> normal (no test)

1 --> yaw axis test inprogress

2 --> roll axis test in progress

3 --> pitch axis test in progress

-1 --> attitude monitoring locked out

+

(reference: KLM Telemetry List, Figure 27)



ATTITUDE_SMODE the attitude control submode word from the TIP CPU

telemetry. The two-byte hex code given in the telemetry has

been stored as a one-byte indicator that can be interpreted as

follows:

+

0 --> nominal

1 --> rate nulling

2 --> yaw gyrocompass

3 --> search

4 --> coast

+

(reference: KLM Telemetry List, Figure 27)



AYAW. It represents the Euler error angle. See the

Programming and Control Handbook (Reduction of CPU Telemetry)

for instructions for the conversion of this integer value to an

angular measure.



CALIBRATION_ERROR is a quality indicator normally set to 0 but

set to 1 by the PDP if the calibration coefficients reported on

this record are questionable or missing (i.e., if there is at

least one non-zero element in CALIB_SCAN_PROBLEM_INDICATOR).



CALIB_CHAN_PROBLEM_INDICATOR a 2-dimensional array of Boolean

codes -- one column for each of the 15 channels -- indicating

the occurrence (1--> yes, 0 --> no) of the channel specific

conditions that follow:

+

(1) no good blackbody counts for scan line

(2) no good space view counts for scan line

(3) no good PRT's for scan line

(4) Some bad blackbody view counts for scan line

(5) Some bad space view counts for scan line

(6) Some bad PRT temps for scan line





CALIB_SCAN_PROBLEM_INDICATOR an array of Boolean codes

indicating the occurrence ( 1--> yes, 0 --> no) of the conditions

given below. These indicators apply to the scan line as a

whole. Indicators for specific channel conditions are given by

the CALIB_CHAN_PROBLEM_INDICATOR.

+

(1) scan not calibrated because of bad time.

(2) scan calibrated using fewer than the

preferred number of scan lines due to

proximity to start or end of dataset or data gap.

(3) no calibration due to bad or missing

PRT data.

(4) calibrated but with marginal PRT data

(5) some uncalibrated channels for this

scan line.

(6) uncalibrated due to instrument mode.

(7) questionable calibration due to antenna position

error of space views.

(8) questionable calibration due to antenna position

error of warm target views.



CLOCK_DRIFT_CORRECTION indicates whether the scan time given in

this record has been corrected for the drift in the spacecraft

clock. A value of 0 indicates no correction has been made, and

a value of 1, that the time in TIME_OF_DAY_OF_SCAN has been

corrected for drift.



CLOCK_DRIFT_DELTA The difference between the time reported on

the data record and that reported by the spacecraft. The time

reported on the data record has been corrected for the drift of

the spacecraft's clock. If the CLOCK_DRIFT_DELTA is added to

TIME_OF_DAY_OF_SCAN, the time reported by the spacecraft will

result. <<missing from current version of SF.>>



COLD_CAL - Space view counts. Two readings for each of AMSU-A channels 1 to 15.



COLD_CAL_POSITION_FLAGS - Space view antenna position flags. Value of 0 indicates

antenna position within tolerance. Defined for 2 antenna readings, 3 AMSU-A devices

(A1-1, A1-2, A2).



COLD_CAL_POSITION_INFO Antenna positions for space views. Two readings for

each AMSU-A device (A1-1, A1-2, A2).



COMPENSATOR_MOTOR_A2 - Digital A telemetry counts for A2 compensator motor.



COMPENSATOR_MOTOR_CUR_A2 - Analog telemetry counts for A2 compensator

motor current.



COMPENSATOR_MOTOR_CUR_A2_FLAG - Invalid (questionable) flag for

A2 compensator motor current from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



COMPENSATOR_TEMP_A2 - Analog telemetry counts for A2 compensator

temperature.

COMPENSATOR_TEMP_A2_FLAG- Invalid (questionable) flag for

A2 compensator temperature from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.

DATA_GAP_INDICATOR Normally zero. If this indicator is set to 1

on a given record, that record is the first one following a data

gap. This indicator is controlled by the PDP, which sets the

indicator based on the patterns of time codes it finds in the

level 1a data.



DAY_OF_YEAR_OF_SCAN the day of the year on which the scan

began, set by the PDP based upon the date and time information

provided in the data stream.



DC/DC_CONVERTER_A1 - digital A PRT telemetry counts for A1 DC/DC converter.



DC/DC_CONVERTER_A2 - digital A PRT telemetry counts for A2 DC/DC converter.



DETECTOR/PREAMP_ASMBLY_A2 - digital A PRT telemetry counts for A2

detector preamp assembly.



DETECTOR/PREAMP_ASSMEBLY_A1 - digital A PRT telemetry counts for A1

detector preamp assembly.



DIG_HOUSEKEEPING_A1 - 4 bytes of A1 digital A housekeeping.



DIG_HOUSEKEEPING_A2 - 4 bytes of A2 digital A housekeeping.



DO_NOT_USE_SCAN is a general quality indicator set by the PDP.

If its value is 1, the scan line should be treated by the

product processors as though it were missing. This flag will be

set if the calibration cannot be performed, or if the earth

location information is missing or erroneous, or if the scan

contains a corrupt time code and a valid time can not be

inferred. <<1b: bytes 29-32, bit 31>>



DRIVE_MOTOR_CUR_A1 - Analog telemetry counts for A1 drive motor current.

DRIVE_MOTOR_CUR_A1_FLAG - Invalid (questionable) flag for

A1 drive motor current from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



DRIVE_MOTOR_CUR_A2 - Analog telemetry counts for A2 drive motor current.

DRIVE_MOTOR_CUR_A2_FLAG - Invalid (questionable) flag for

A2 drive motor current from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



EARTH_LOCATION_ERROR Normally zero, this indicator indicates the

occurrence of a problem in earth location.



EARTH_LOCATION_PROBLEM_INDICATOR

(1) not earth-located because of bad time

(2) questionable earth location because of

questionable time code

(3) questionable earth location because of marginal

agreement with reasonableness check

(4) earth location probably bad -- fails

reasonableness check.

(5) earth location questionable because of antenna

positions out of tolerance.



EARTH_LOC_ATTITUDE_CORRECTED - flag to indicate whether earth

location attitude correction passed reasonableness test.

Value of 1 indicates reasonableness test passed.



EARTH_LOC_INDICATOR - TBD



FEED_HORN_A2 - digital A PRT telemetry counts for A2 feed horn



FEED_HORN_PRT_A1 - digital A PRT telemetry counts for A1 feed horn;

there are 2 values, one for A1-1 and one for A1-2 device.

FIRST_GOOD_TIME_AFTER_UPDATE The spacecraft clock has been

updated. This scan is the first subsequent scan whose time is

judged good. Set by the PDP. <<1b: bytes 29-32, bit 26>>



GDO_VOLTAGE_CH1 - Analog telemetry counts for channel 1 GDO voltage.



GDO_VOLTAGE_CH15_A1 - Analog telemetry counts for channel 15 GDO voltage.



GDO_VOLTAGE_CH15_A1_FLAG- Invalid (questionable) flag for

channel 15 GDO voltage from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.

GDO_VOLTAGE_CH1_FLAG- Invalid (questionable) flag for

channel 1 GDO voltage rom analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



GDO_VOLTAGE_CH2 - Analog telemetry counts for channel 2 GDO voltage.



GDO_VOLTAGE_CH2_FLAG- Invalid (questionable) flag for

channel 2 GDO voltage from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



GDO_VOLTAGE_CHANS3/8 - Analog telemetry counts for GDO voltage for channels

3 - 8 (6 values).



GDO_VOLTAGE_CHANS3/8_FLAG - Invalid (questionable) flags for

GDO voltage for channels 3 - 8 from analog telemetry (6 values). Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.

GDTIME Geometric Data Time taken from the TIP CPU telemetry.



IF_AMP_CHANS_9/14_A1 - digital A PRT telemetry counts for IF amplifier for channels

9 to 14 (6 values).



IF_AMP_CH_11/14_A1 - digital A PRT telemetry counts for IF amplifier for channels

11 to 14 (one value).



INSTRUMENT_STATUS_CHANGE - Flag set to 1 if A1 or A2 instrument status changed

this scan.



LAT_LON_DEGREES The geodetic latitude and longitude, in that

order, of each of the fields of view along the scan line. The

latitude's range is +/- 90 degrees, with 0 at the equator and

positive angles to the north. The longitude is measured from

Greenwich, with positive values to the east; its range is +/-

180 degrees.



LOCAL_AZIMUTH_ANGLE the angle between the projections onto

the tangent plane of lines drawn from the viewed point to the

sun and from the viewed point to the satellite. It is measured

from sun to satellite and has a range of +/- 180 degrees; angles

eastward from the sun are positive.



LOCAL_OSCIL_CH15_PRT_A1 - digital A PRT telemetry counts for local oscillator

for channel 15.



LOCAL_OSCIL_CH3_TO_8_PRT_A1 - digital A PRT telemetry counts for local oscillator

for channels 3 to 8 (6 values).

LOCAL_ZENITH_ANGLE (aka satellite zenith angle) the angle from a

line drawn from the viewed point to the satellite and one from

the viewed point normal to its tangent plane. The range of

satellite zenith angle is 0 to 90 degrees.



LO_CH_1_A2 - digital A PRT telemetry counts for local oscillator for channel 1.



LO_CH_2_A2 - digital A PRT telemetry counts for local oscillator for channel 2.



MAJOR_FRAME_COUNT The TIP major frame counter of the major

frame from which this scan line was extracted. Set by the PDP

directly using the ordinal number of the TIP major frame in

the 1A dataset.



MF_CPU_FILLER - One flag for each of 80 minor frames associated with scan.

Flag set to 1 indicates minor frame in dump mode (CPU data is filler).



MF_MISSING - One flag for each of 80 minor frames associated with scan.

Flag set to 1 indicates minor frame is missing.



MF_QUESTIONABLE - One flag for each of 80 minor frames associated with scan.

Flag set to 1 indicates minor frame is questionable. Minor frame is questionable

if any of the following conditions occur:

bad TIP major frame counter; bad TIP minor frame counter; bad AMSU major

frame counter; bad AMSU minor frame counter; bad TIP time; bad TIP status;

bad TIP parity; frame not in sequence.



MIXER_IF_AMP_CH_1_A2 - digital A PRT telemetry counts for mixer IF amplifier for

channel 1.



MIXER_IF_AMP_CH_2_A2 - digital A PRT telemetry counts for mixer IF amplifier for

channel 2.



MIX_IF_AMP_CH_15_A1 - digital A PRT telemetry counts for mixer IF amplifier for

channel 15.



MIX_IF_AMP_CH_3/8_A1 - digital A PRT telemetry counts for mixer IF amplifier for

channels 3 to 8 (6 values).



MIX_IF_AMP_CH_9/14_A1 - digital A PRT telemetry counts for mixer IF amplifier for

channels 9 to 14 (1 value).



N15VDC_ANTENNA_A1 - Analog telemetry counts for -15VDC A1 antenna drive.



N15VDC_ANTENNA_A1_FLAG - Invalid (questionable) flag for

-15VDC A1 antenna drive rom analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



N15VDC_ANTENNA_A2 - Analog telemetry counts for -15VDC A2 antenna drive.



N15VDC_ANTENNA_A2_FLAG - Invalid (questionable) flag for

-15VDC A2 antenna drive from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



N15VDC_PLL_A1 - Analog telemetry counts for -15VDC A1-1 phase lock loop.



N15VDC_PLL_A1_FLAG- Invalid (questionable) flag for

-15VDC A1-1 phase lock loop from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.

N15VDC_SIGNAL_A1 - Analog telemetry counts for -15VDC A1 signal processing.



N15VDC_SIGNAL_A1_FLAG - Invalid (questionable) flag for

-15VDC A1 signal processing from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



N15VDC_SIGNAL_A2 - Analog telemetry counts for -15VDC A2 signal processing.



N15VDC_SIGNAL_A2_FLAG - Invalid (questionable) flag for

-15VDC A2 signal processing from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.

NAVIGATION_STATUS_BIT_FIELD - - 4 byte packed bit word with bits

defined as in 1b data record format under Navigation Status Bit

Field.



OBSERVATIONS The radiometric counts of earth views from the

instrument during the current scan (15 channels, 30 earth views).



ORBIT_NODE This field indicates the direction of the spacecraft

at the time of the scan. A value of zero indicates the

spacecraft is heading north (ascending), a value of one that it

is going south (descending).



P15VDC_ANTENNA_A1 - Analog telemetry counts for +15VDC A1 antenna drive.



P15VDC_ANTENNA_A1_FLAG- Invalid (questionable) flag for

+15VDC A1 antenna drive from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P15VDC_ANTENNA_A2 - Analog telemetry counts for +15VDC A2 antenna drive.



P15VDC_ANTENNA_A2_FLAG - Invalid (questionable) flag for

+15VDC A2 antenna drive from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P15VDC_PLL_A1 - Analog telemetry counts for +15VDC channels 9-14

phase lock loop (one value).



P15VDC_PLL_A1_FLAG - Invalid (questionable) flag for

+15VDC channels 9 - 14 phase lock loop from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P15VDC_SIGNAL_A1 - Analog telemetry counts for +15VDC A1 signal processing.



P15VDC_SIGNAL_A1_FLAG - Invalid (questionable) flag for

+15VDC A1 signal processing from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P15VDC_SIGNAL_A2 - Analog telemetry counts for +15VDC A2 signal processing.



P15VDC_SIGNAL_A2_FLAG - Invalid (questionable) flag for

+15VDC A2 signal processing from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P5VDC_ANTENNA_A1 - Analog telemetry counts for +5VDC A1 antenna drive.



P5VDC_ANTENNA_A1_FLAG - Invalid (questionable) flag for

+5VDC A1 antenna drive from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P5VDC_ANTENNA_A2 - Analog telemetry counts for +5VDC A2 antenna drive.



P5VDC_ANTENNA_A2_FLAG - Invalid (questionable) flag for

+5VDC A2 antenna drive from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P5VDC_SIGNAL_A1 - Analog telemetry counts for +5VDC A1 signal processing.



P5VDC_SIGNAL_A1_FLAG - Invalid (questionable) flag for

+5VDC A1 signal processing from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P5VDC_SIGNAL_A2 - Analog telemetry counts for +5VDC A2 signal processing.



P5VDC_SIGNAL_A2_FLAG - Invalid (questionable) flag for

+5VDC A2 signal processing from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P8.5VDC_PLL_A1 - Analog telemetry counts for +8.5VDC channels 9-14

phase lock loop (one value).



P8.5VDC_PLL_A1_FLAG - Invalid (questionable) flag for

+8.5VDC channels 9 - 14 phase lock loop from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P8VDC_RECEIVER_A1 - Analog telemetry counts for +8VDC A1 receiver amplifier.



P8VDC_RECEIVER_A1_FLAG - Invalid (questionable) flag for

+8VDC A1 receiver amplifier from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



P8VDC_RECEIVER_A2 - Analog telemetry counts for +8VDC A2 receiver.



P8VDC_RECEIVER_A2_FLAG - Invalid (questionable) flag for

+8VDC A2 receiver from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



PITCH_ERROR_CORRECTION_FIXED the value provided in the TIP's CPU

parameter APITCH. It represents the Euler error angle. See the

Programming and Control Handbook (Reduction of CPU Telemetry)

for instructions for the conversion of this integer value to an

angular measure.



PLLO_PRIMARY_DETECT_A1 - Analog telemetry counts for PLLO primary lock

detect (PLLO # 1).



PLLO_PRIMARY_DETECT_A1_FLAG - Invalid (questionable) flag for

PLLO primary (PLLO #1) lock detect from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



PLLO_PRT_A1 - digital A PRT telemetry counts for channels 9 - 14 PLLO

reference oscillator.



PLLO_REDUNDANT_DETECT_A1 - Analog telemetry counts for PLLO redundant lock

detect (PLLO # 2).

PLLO_REDUNDANT_DETECT_A1_FLAG - Invalid (questionable) flag for

PLLO redundant (PLLO #2) lock detect from analog telemetry. Value of 1 indicates

that the value of the analog telemetry item could not be updated during this scan.



PLL_LO1_CH9_TO_14_PRT_A1 - digital A PRT telemetry counts for channels 9 - 14

PLLO #1 (primary).



PLL_LO2_CH9_TO_14_PRT_A1 - digital A PRT telemetry counts for channels 9 - 14

PLLO #2 (primary).



POSITION_FLAGS - Flags for antenna positions for each scene (earth) field of view.

If set to 1, flag indicates antenna position is out of nominal range for this view.

Flags for 2 antenna readings, 30 fields of view, 3 devices (A1-1, A1-2, A2).



POSITION_INFORMATION - Antenna position in counts for each earth field of view.

Positions for 2 antenna readings, 30 fields of view, 3 devices (A1-1, A1-2, A2).



PRI_CAL_COEFFS The calibration coefficients computed by the

PDP for AMSU-A channels using the primary calibration

algorithm, as well as primary calibration parameters stored in

CPIDS. These are the calibration coefficients that should be

used to convert radiometric counts to radiance (coefficients a0, a1, a2

for 15 channels)..



QUALITY_INDICATOR_BIT_FIELD - Corresponds to bits in 4 byte word defined in

1b format for Quality Indicator Bit Field in data record.



RF_MUX_A2 - digital A PRT telemetry counts for A2 RF Mux.



RF_MUX_PRT_A1 - digital A PRT telemetry counts for RF Mux for A1-1, A1-2

(2 values).



RF_SHELF_A1-1 - digital A PRT telemetry counts for A1-1 RF Shelf.



RF_SHELF_A1-2 - digital A PRT telemetry counts for A1-2 RF Shelf.



RF_SHELF_A2 - digital A PRT telemetry counts for A2 RF Shelf.



RF_SHELF_TEMPS_A1 - Analog telemetry counts for A1-1, A1-2 RF Shelf

temperatures (2 values).



RF_SHELF_TEMPS_A1_FLAG - Invalid (questionable) flag for

A1-1, A1-2 RF Shelf temperatures (2 values) from analog telemetry.

Value of 1 indicates that the value of the analog telemetry item could not be

updated during this scan.



RF_SHELF_TEMP_A2 - Analog telemetry counts for A2 RF Shelf temperature.



RF_SHELF_TEMP_A2_FLAG - Invalid (questionable) flag for

A2 RF Shelf temperature from analog telemetry.

Value of 1 indicates that the value of the analog telemetry item could not be

updated during this scan.

ROLL_ERROR_CORRECTION_FIXED the value provided in the TIP's CPU

parameter AROLL. It represents the Euler error angle. See the

Programming and Control Handbook (Reduction of CPU Telemetry)

for instructions for the conversion of this integer value to an

angular measure.



S/C_ALTITUDE The spacecraft altitude in kilometers. Computed

by AELDS, rounded by PDP to nearest km, and stored as an integer.



SCANNER_MOTOR_TEMPS_A1 - Analog telemetry counts for A1-1, A1-2

scanner motor temperatures (2 values).



SCANNER_MOTOR_TEMPS_A1_FLAG - Invalid (questionable) flag for

A1-1, A1-2 scanner motor temperatures (2 values) from analog telemetry.

Value of 1 indicates that the value of the analog telemetry item could not be

updated during this scan.

SCANNER_MOTOR_TEMPS_A2 - Analog telemetry counts for A2 scanner motor

temperature.



SCANNER_MOTOR_TEMPS_A2_FLAG - Invalid (questionable) flag for

A2 scanner motor temperature from analog telemetry.

Value of 1 indicates that the value of the analog telemetry item could not be

updated during this scan.

SCAN_LINE_NUMBER the relative scan number within the period of

the 1b data set, starting with 1. Scan_line_number will take

into account missing scans and thus attempt to give an accurate

count of the number of scan lines generated by the spacecraft.

Set by the PDP.



SCAN_MOTOR_A2 - flag from the digital B data in TIP indicating the

status of the scan motor mode. 1 --> high power; 0 --> low

power.



SCAN_MOTOR_PRT_A1 - flag from the digital B data in TIP indicating the

status of the scan motor mode. 1 --> high power; 0 --> low

power.



SEC_CAL_COEFFS - The calibration coefficients computed by the

PDP for AMSU-A channels using the secondary calibration

algorithm, as well as secondary calibration parameters stored in

CPIDS. These are the calibration coefficients that should be

used to convert radiometric counts to radiance (coefficients a0, a1, a2

for 15 channels).



SOLAR_ZENITH_ANGLE the angle between a line drawn from the

viewed point to the sun and one from the viewed point normal to

its tangent plane. The range of solar zenith angle is 0 to

180 degrees.



SUBREFLECTOR_A2 - digital A PRT telemetry counts for A2 subreflector.



SYNC_SEQUENCE_A1 - Sync sequence for A1 digital A telemetry.

Valid sync sequence is 3 bytes of FF Hex in each byte.



SYNC_SEQUENCE_A2 - Sync sequence for A2 digital A telemetry.

Valid sync sequence is 3 bytes of FF Hex in each byte.



TEMP_SENSOR_REF_VOLT_A1 - digital A PRT telemetry counts for A1 temperature

sensor reference voltage.



TEMP_SENSOR_REF_VOLT_A2 - digital A PRT telemetry counts for A2 temperature

sensor reference voltage.

TIME_ERROR The current scan line does not have the expected time

and the fact cannot be explained by a detected data gap or by a

scheduled correction to the spacecraft clock. Generally this

means that the difference between the time of the current scan

and the most recent previous scan having a good time is not

evenly divisible by the scan period. Set by the PDP based upon

major/minor frame accounting and the availability of time data

from the spacecraft. <<1b: bytes 29-32, bit 30>>



TIME_OF_DAY_OF_SCAN the time of day in milliseconds of the start

of the scan. Set by the PDP based upon the date and time

information provided in the data stream. Scan times are obtained

from the time of the TIP major frame with an increment added

for each scan period. The scan time refers to the time midway

through the first field of view of the scan. If the time

of the TIP major is not known and in the case of embedded AIP or

TIP, the time will be inferred from the AVHRR frame (GAC or

HRPT).



TIME_PROBLEM_INDICATOR provides an array of boolean codes

indicating the occurrence (or not) of the following conditions:

+

(1) Time received from the s/c was

obviously bad. The time on this scan

has been inferred from those on nearby

scan lines.

(2) Bad time received from s/c and can't

infer one reliably.

(3) Pattern of scan times changed. May be

related to clock update.

(4) Spare.



UNIT_ID_SN_A1 - Unit ID and serial number for A1.



UNIT_ID_SN_A2 - Unit ID and serial number for A2.



WARM_CAL - Warm target view counts. Two readings for each of AMSU-A

channels 1 to 15.



WARM_CAL_POSITION_FLAGS - Warm target view antenna position flags.

Value of 0 indicates antenna position within tolerance.

Defined for 2 antenna readings, 3 AMSU-A devices

(A1-1, A1-2, A2).

WARM_CAL_POSITION_INFO - Antenna positions for space views. Two readings for

each AMSU-A device (A1-1, A1-2, A2).

WARM_LOAD_PRT_A1_1 - digital A PRT telemetry counts for A1-1 PRT's.

One value for each of 5 PRT's (stored in digital A telemetry order; i.e.

PRT 1, 2, 3, 4, center).



WARM_LOAD_PRT_A1_2 - digital A PRT telemetry counts for A1-1 PRT's.

One value for each of 5 PRT's (stored in digital A telemetry order; i.e.

PRT 1, 2, 3, 4, center).



WARM_LOAD_PRT_A2 - digital A PRT telemetry counts for A1-1 PRT's.

One value for each of 7 PRT's (stored in digital A telemetry order; i.e.

PRT center, 1, 2, 3, 4, 5, 6).



WARM_LOAD_TEMPS_A1 - Analog telemetry counts for A1-1, A1-2 warm

load temperatures (2 values).



WARM_LOAD_TEMPS_A1_FLAG - Invalid (questionable) flag for

A1-1, A1-2 warm load temperatures from analog telemetry (2 values).

Value of 1 indicates that the value of the analog telemetry item could not be

updated during this scan.

WARM_LOAD_TEMP_A2 - Analog telemetry counts for A2 warm

load temperature.



WARM_LOAD_TEMP_A2_FLAG - Invalid (questionable) flag for

A2 warm load temperature from analog telemetry.

Value of 1 indicates that the value of the analog telemetry item could not be

updated during this scan.



YAW_ERROR_CORRECTION_FIXED the value provided in the TIP's CPU

parameter AYAW. It represents the Euler error angle. See the

Programming and Control Handbook (Reduction of CPU Telemetry)

for instructions for the conversion of this integer value to an

angular measure.



YEAR_OF_SCAN the year in which the scan began. It will contain

the year as a four-digit number. It is set by the PDP based upon

the date and time information provided in the data stream.